TDK Alpha 1500W | Modular Power Supplies 

1 to 16 Outputs Modular. Standard or Configurable. No Minimum load, Rapid Connection, Wide Range Input. EN61000-3-2 Compliant. Class B Conducted.

Features 

  • Fast-on output connection 
  • Worldwide safety approvals 
  • Up to 16 outputs 
  • Medical approval available (CA1000)  
  • 3 year warranty
Benefits

  • Reduces installation time/errors
  • Supports global use
  • Eliminates need for additional supplies
  • Simplifies approval process

Input

  • Input Voltage Alpha 1500 85 - 264Vac (1000W below 150Vac input)
  • Input Frequency 47 - 63Hz (440Hz with reduced PFC - consult sales office)
  • Input Fuse 20A / 250Vac HBC Fast acting (not user accessible)
  • Inrush Current <50A at 25°C and 264Vac (cold start)
  • Leakage Current 1.1mA max at 264Vac & 63Hz (lower leakage versions available, see configuring guide)

Output

  • Voltage / Current See output voltages table
  • Turn on time 1.5s max at 90Vac (150Vac for CA1500) and 100% rated output power
  • Rise time <50ms to 90% of voltage, monotonic rise above 10%
  • Turn on overshoot <5% or 250mV Load type dependent, no overshoot with resistive load
  • Efficiency up to 75% at 230Vac & 100% rated power, configuration dependent
  • Hold up 13ms min at 90Vac and 100% rated power (8ms for CA1500 at 207Vac & 100% rated power)
  • Ripple and Noise <2% or 100mV pk-pk, using EIAJ test method & 20MHz bandwidth C and W modules <3%
  • Voltage Accuracy <1% of set voltage
  • Remote Sense Yes standard on single output modules
  • Minimum Load No on any output
  • Temperature Coefficient <0.02% of rated voltage per °C
  • Load Regulation <0.5% or 25mV for 0-100% load change, with sense connected (<2% without) T module < 2.5%
  • Line Regulation <0.5% for 90-264Vac input change (210 - 264Vac for CA1500) L and T modules <25mV
  • Cross Regulation <0.2% for 100% load change on any output
  • Transient Response <10% of set voltage for 50% load change (above 25% load)
  • Recovery 500µs for recovery to 1% or 100mV of set voltage (1000µs for ‘S’ module)
  • Over Voltage Protection Standard for all outputs
  • Over Current Protection Standard for all outputs
  • Short Circuit Protection Yes
  • Over Temperature Protection Yes shuts down all outputs. Cycle ac off/on to reset 
  • Shutdown temperature varies according to ambient, output power and input voltage

Approvals / Accreditations

  • IEC/EN 62368-1, UL62368-1 / CSA 22.2 No 62368-1 File E135494
  • IEC/EN 60950-1, UL60950-1 / CSA 22.2 No 60950-1 File E135494
  • IEC/EN 60601-1, UL/CSA 60601-1, ANSI/AAMI ES60601-1
  • CAN/CSA-C22.2 No 60601-1-08
  • File E349607
  • (not CA1500, only for LL, RL and TL leakage variants)
  • CE Mark (EN62368-1) Low Voltage Directive (LVD), electromagnetic compatibility (EMC) and Restriction of Hazardous Substances (RoHS)
  • UKCA (EN62368-1) Electrical Equipment (Safety) Regulations, electromagnetic compatibility (EMC) and Restriction of Hazardous Substances (RoHS)
  • CB certificate and Report available on request Please check with technical sales for status of approvals
  • Manufactured under the control of ISO9001 and ISO13485 (including risk management